User's manualRetain for future useAltivar 71"Controller Inside" CardVW3 A3 501
10Hardware setupDescription of terminalsTerminal Function24V Power supply for the "Controller Inside" card, logic outputs and analog outputs
11Hardware setupCharacteristicsElectrical characteristicsCharacteristics of the application programCharacteristics of the CANopen communication portPo
12Hardware setupSchemesCard powered by the driveOnly if the power consumption is less than 200 mA; otherwise use an external power supply.Card powered
13Hardware setupConnection to a CANopen busPinout for the CANopen 9-way SUB-D connectorUse a straight connector (catalog number TSX CAN KCDF 180T) to
14Hardware setupExample of connection to a CANopen busDescriptionReference numberLengthmCatalog numberAltivar 71 driveequipped with a "Controller
15Hardware setupConnecting the "Controller Inside" card to a PCCharacteristics of the programming portThe RJ45 connector is shielded and con
16Hardware setupData backup batteryThe "Controller Inside" card has a non-volatile RAM (NVRAM) which is needed to store variables. A lithium
17ConfigurationConfiguring the switchesThe "Controller Inside" card has a block of 4 switches as illustrated below.Write protection switchTh
18DiagnosticsLEDsThe "Controller Inside" card is equipped with five LEDswhich can be seen through the window in the Altivar 71cover.LED Colo
19DiagnosticsI/O monitoringThe values of all the "Controller Inside" card logic and analog I/O can be displayed on the graphic display termi
20DiagnosticsCard faultThe [internal com. link] (ILF) fault appears when serious problems arise:- Hardware fault in the Controller Inside card- Dial
21Operation using the graphic display terminalFactory-loaded programController Inside menuController Inside card Modbus addressThe [Modbus add Prg C.]
22Operation using the graphic display terminalSetting the date and timeIn the [1.14 PROGRAMMABLE CARD] menu, [DATE/TIME SETTINGS] sub-menu, you can se
23Operation using the graphic display terminalExample of a special programThe name of menu 1.14 has been customized.The application parameters are edi
24Operation using the integrated display terminalFactory-loaded programController Inside menuThe [Modbus add Prg C.] (AMOA) parameter can be set, as i
2005-04atv71_Controller_Inside_EN_V1
3SommaireBefore you begin_____________________________________________________________________________________________ 4Documentation structure______
4Before you beginRead and understand these instructions before performing any procedure on this drive.DANGERHAZARDOUS VOLTAGE• Read and understand the
5Documentation structureInstallation manualThis manual describes:• Assembly• How to connect the driveProgramming manualThis manual describes:• The fun
6IntroductionPresentationThe “Controller Inside” programmable card is used to adapt the variable speed drive to specific applications by integrating c
7IntroductionDialogMaster CANopen communicationCommunication with a PLCHuman-machine dialog with the application programmed in the “Controller Inside”
8IntroductionClockA clock backed up by a lithium battery makes it possible to have a log of events that have occurred. When the “Controller Inside”pro
9Hardware setupReceipt• Check that the card catalog number marked on the label is the same as that on the delivery note corresponding to the purchase