VVDED397047US R8/01 ALTIVAR
58 Keypad Display
08/01 Chapter 2 Menus
© 19982001 Schneider Electric All Rights Reserved
71
(For a 50 Hz supply: Ns = 3000 rpm for a motor with two poles,
1500 rpm for a motor with four poles, 1000 rpm for a motor with six
poles, and 750 rpm for a motor with eight poles.
For a 60 Hz supply: Ns = 3600 rpm for a motor with two poles,
1800 rpm for a motor with four poles, 1200 rpm for a motor with six
poles, and 900 rpm for a motor with eight poles.)
Example calculation: for a motor with four poles, 1430 rpm given on
the rating plate, and a 50 Hz supply
g = (1500 1430) / 1500 = 0.0466
Brake release frequency = 0.0466 x 50 = 2.4 Hz
Brake release current (Ibr):
Adjust the brake release current to the nominal current indicated on
the motor.
NOTE: The values indicated (release current and release frequency)
correspond to theoretical values. If during testing, the torque is
insufficient using these theoretical values, retain the brake release
current at the nominal motor current and lower the brake release
frequency (up to 2/3 of the nominal slip). If the result is still not
satisfactory, return to the theoretical values and then increase the
brake release current (the maximum value is imposed by the speed
controller) and increase the brake release frequency gradually.
Acceleration time:
It is advisable to set the acceleration ramps to more than
0.5 seconds. Ensure that the drive controller does not exceed the
current limit.
The same recommendation applies for deceleration. A braking
resistor should be used on overhauling loads.
Brake release delay (brt):
Adjust according to the time required for the mechanical brake to
open.
Brake engage frequency (bEN):
Set to twice the nominal slip (in our example 2 x 2.4 = 4.8 Hz). Then
adjust according to observed results.
Brake engage delay (bEt):
Adjust according to the time required for the mechanical brake to
close.